ORIGINAL ARTICLE |
|
Year : 2011 | Volume
: 5
| Issue : 1 | Page : 11-14 |
|
In vitro function of random donor platelets stored for 7 days in composol platelet additive solution
Ashish Gupta1, Tulika Chandra2, Ashutosh Kumar3
1 Department of Transfusion Medicine and Blood Bank, Chhatrapati Shahuji Maharaj Medical University, Lucknow, Uttar Pradesh; Department of Pathology, Chhatrapati Shahuji Maharaj Medical University, Lucknow, Uttar Pradesh, India 2 Department of Transfusion Medicine and Blood Bank, Chhatrapati Shahuji Maharaj Medical University, Lucknow, Uttar Pradesh, India 3 Department of Pathology, Chhatrapati Shahuji Maharaj Medical University, Lucknow, Uttar Pradesh, India
Correspondence Address:
Tulika Chandra Department of Transfusion Medicine and Blood Bank, Chhatrapati Shahuji Maharaj Medical University, Lucknow, Uttar Pradesh - 226 003 India
 Source of Support: Council of Science and Technology,
Lucknow, Uttar Pradesh, Conflict of Interest: None  | Check |
DOI: 10.4103/0973-6247.75969
|
|
Background and Aim: Platelets are routinely isolated from whole blood and stored in plasma for 5 days. The present study was done to assess the in vitro function of random donor platelets stored for 7 days in composol platelet additive solution at 22°C. Materials and Methods: The study sample included 30 blood donors of both sex in State Blood Bank, CSM Medical University, Lucknow. Random donor platelets were prepared by platelet rich plasma method. Whole blood (350 ml) was collected in anticoagulant Citrate Phosphate Dextrose Adenine triple blood bags. Random donor platelets were stored for 7 days at 22°C in platelet incubators and agitators, with and without additive solution. Results: Platelet swirling was present in all the units at 22°C on day 7, with no evidence of bacterial contamination. Comparison of the mean values of platelet count, platelet factor 3, lactate dehydrogenase, pH, glucose and platelet aggregation showed no significant difference in additive solution, whereas platelet factor 3, glucose and platelet aggregation showed significant difference (P < 0.001) on day 7 without additive solution at 22°C. Conclusion: Our study infers that platelet viability and aggregation were best maintained within normal levels on day 7 of storage in platelet additive solution at 22°C. Thus, we may conclude that in vitro storage of random donor platelets with an extended shelf life of 7 days using platelet additive solution may be advocated to improve the inventory of platelets. |
|
|
|
[FULL TEXT] [PDF]* |
|
 |
|