Evaluation of the red cell hemolysis in packed red cells during processing and storage


Department of Transfusion Medicine, Indraprastha Apollo Hospitals, Sarita Vihar, New Delhi 110 076, India

Correspondence Address:
R N Makroo
Department of Transfusion Medicine, Indraprastha Apollo Hospitals, Sarita Vihar, New Delhi 110 076
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0973-6247.75970

Rights and Permissions

Introduction : Storage of red cells causes a progressive increase in hemolysis. In spite of the use of additive solutions for storage and filters for leucoreduction, some amount of hemolysis is still inevitable. The extent of hemolysis, however, should not exceed the permissible threshold for hemolysis even on the 42 nd day of storage. Study Design and Methods: Eighty units of packed red cells, 40 stored in SAGM post leucoreduction and 40 in ADSOL without leucoreduction filters, were evaluated for plasma hemoglobin by HemoCue Plasma Hemoglobin analyzer on the day of collection and on the 7 th , 14 th , 21 st , 28 th , 35 th and 42 nd days thereafter. The hemoglobin and hematocrit were also noted for all these units by the Beckman and Coulter analyzer. Percentage hemolysis was then calculated. Observations: Hemolysis progressively increased with the storage period in all the stored red cell units (SAGM as well ADSOL). However, on day 42 nd of storage, free hemoglobin in all the red cell units was within the permissible level (which is 0.8% according to the Council of Europe guidelines and 1% as per the US FDA guidelines). The mean percentage hemolysis was slightly higher in the SAGM-containing bags with an integral leucoreduction filter as compared to the bags containing ADSOL. However this difference was marginal and not statistically significant. Conclusion: Hemolysis of the red cells increases with storage. However, maximum hemolysis does not exceed the permissible limits at any time thereby indicating the effect of optimum processing and storage conditions on red cell hemolysis.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed7365    
    Printed461    
    Emailed3    
    PDF Downloaded166    
    Comments [Add]    
    Cited by others 13    

Recommend this journal

 

Association Contact us | Sitemap | Advertise | What's New | Copyright and Disclaimer | Privacy Notice


© 2006 - Asian Journal of Transfusion Science | Published by Wolters Kluwer - Medknow
Online since 10th November, 2006