Asian Journal of Transfusion Science
Home About Journal Editorial Board Search Current Issue Ahead of print Back Issues Instructions Subscribe Login  Users: 280 Print this page  Email this page Small font sizeDefault font sizeIncrease font size 
CASE REPORT
Year : 2023  |  Volume : 17  |  Issue : 1  |  Page : 121-124

A conservative approach in finding compatible blood for a patient with sickle cell disease having multiple alloantibodies


Department of Research Centre, Lok Samarpan Raktadan Kendra and Research Centre, Surat, Gujarat, India

Correspondence Address:
Sanmukh Ratilal Joshi
Department of Research Centre, Lok Samarpan Raktadan Kendra and Research Centre, Minibazar, Varachha Road, Surat - 395 006, Gujarat
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ajts.ajts_114_22

Rights and Permissions

BACKGROUND: Sickle cell disease (SCD) patients may develop multiple alloantibodies that pose problem in finding compatible blood for transfusion and require crossmatching with large number of blood. AIM: The aim of the present study was to find compatible blood with reduced cost by adopting a conservative approach. MATERIALS AND METHODS: A step-by-step approach using tube technique, antibodies in original serum, and the saved test supernatant (TS) in search of compatible blood for transfusion purposes. RESULTS: 32 years SCD patient grouped A with multiple antibodies required transfusion. A total of 641 red blood cell (RBC) units of groups A and O were crossmatched using serum and the TS by tube method. Of 138 units tested using the serum at 4°C, 124 units showed direct agglutination in the saline phase and the remaining 14 units were processed through low ionic strength solution (LISS)-IAT, of which 2 units were compatible even by the gel-IgG-card method. The TS, saved from the tests on serum, was used in an identical manner as that of the serum to screen additional 503 units by saline tube method at 4°C units showed direct agglutination of the RBCs of 428 units, hence were removed from inventory for this patient. The remaining 75 units were tested by the LISS-IAT-tube method at 37°C, of which 8 units were found compatible but only 2 units were clear compatible by the gel-IgG-card method. As such, 4 units compatible by the sensitive gel-IgG-card method were issued for transfusion purposes. CONCLUSION: The new approach on using the saved TS consumed less of the patient's blood specimen, and the use of the tube method in screening and eliminating a large chunk of incompatible blood units has proved economical if compared with the use of the only gel-IgG-cards device in the entire maneuvering.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed286    
    Printed23    
    Emailed0    
    PDF Downloaded29    
    Comments [Add]    

Recommend this journal

 

Association Contact us | Sitemap | Advertise | What's New | Copyright and Disclaimer | Privacy Notice


© 2006 - Asian Journal of Transfusion Science | Published by Wolters Kluwer - Medknow
Online since 10th November, 2006