Home
About Journal
Editorial Board
Search
Current Issue
Ahead of print
Back Issues
Instructions
Subscribe
Reader Login
Users: 111
Export selected to
Endnote
Reference Manager
Procite
Medlars Format
RefWorks Format
BibTex Format
Citation statistics : Table of Contents
2017| January-June | Volume 11 | Issue 1
Online since
February 22, 2017
Archives
Previous Issue
Next Issue
Most popular articles
Most cited articles
Show all abstracts
Show selected abstracts
Export selected to
Cited
Viewed
PDF
REVIEW ARTICLE
Blood transfusion safety; current status and challenges in Nigeria
John C Aneke, Chide E Okocha
January-June 2017, 11(1):1-5
DOI
:10.4103/0973-6247.200781
PMID
:28316432
The attainment of blood transfusion safety in Nigeria (and probably the rest of Sub-Saharan Africa) remains an uphill task due to a number of factors, ranging from shortage of blood, poor implementation of blood transfusion guidelines, infrastructural deficits to high prevalence of transfusion-transmissible infections (TTIs), particularly hepatitis and human immune deficiency viruses. We reviewed available data on blood transfusion practices and safety in Nigeria using the PubMed, PubMed Central, Google Scholar, and African Index Medicus search engines, through a combination of word and phrases relevant to the subject. The World Health Organization has been in the forefront of efforts to establish safe, available, and affordable blood transfusion services in most parts of Africa through encouraging adequate blood donor recruitment, donor blood testing, and collection as well developing strategies for the rational use of blood. Even though modest improvement has been recorded, particularly with regards to donor blood screening for common TTIs, considerable efforts are needed in the form of robust public enlightenment campaigns (on blood donation) and continuous system improvement to drive the current transfusion practices in the country toward safety and self-sustenance.
[ABSTRACT]
[FULL TEXT]
[PDF]
[Mobile Full text]
[EPub]
[CITATIONS]
[PubMed]
21
7,340
393
ORIGINAL ARTICLES
Antibody titers in Group O platelet donors
Anita Amar Tendulkar, Puneet Ashok Jain, Sanjay Velaye
January-June 2017, 11(1):22-27
DOI
:10.4103/0973-6247.200765
PMID
:28316436
Background and Objectives:
The occurrence of hemolysis due to transfusion of ABO plasma-incompatible platelets (PLTs) is challenging. There has been no consensus for critical antibody titers in the transfusion community. This study was conducted to understand the trends of anti-A and anti-B antibody titer levels in O group donors and to identify any specific patterns of distribution in relation to age and gender.
Materials and Methods:
A total of 1635 Group O PLT donors were randomly selected for this prospective study. Serial 2-fold doubling dilutions were prepared for each sample to calculate the titer of anti-A and anti-B in a standard 96 well micro-plate. Tube technique was used for comparison with the microplate method for 100 samples.
Results:
Out of 1635 donors, 1430 (87.46%) were males and 205 (12.54%) were females. The median titer for anti-A and anti-B was 128 with range from 4 to 2048. Spearman's correlation coefficient for microplate versus tube technique was estimated to be 0.803 (
P
< 0.01, two-tailed). 57.12% and 51.19% of all donors had titers ≥128 for anti-A and anti-B, respectively. The geometric mean of anti-A and anti-B was 155.7 and 137.28, respectively. The titers were significantly higher (
P
< 0.001) in female donors. An inverse relation between titer levels and age was seen.
Conclusion:
Microplate can be used to perform titers in resource-constrained settings. Screening for critical titers in O group donors is essential as they are more implicated in hemolytic transfusion reactions. In the absence of a global consensus on this topic, institutes may need to formulate their own guidelines on handling ABO plasma-incompatible PLT transfusions.
[ABSTRACT]
[FULL TEXT]
[PDF]
[Mobile Full text]
[EPub]
[CITATIONS]
[PubMed]
12
6,501
174
Comparison of deferasirox and deferoxamine effects on iron overload and immunological changes in patients with blood transfusion-dependent β-thalassemia
Hayder M Al-Kuraishy, Ali I Al-Gareeb
January-June 2017, 11(1):13-17
DOI
:10.4103/0973-6247.200768
PMID
:28316434
Introduction:
Beta-thalassemias are a cluster of inherited (autosomal recessive) hematological disorders prevalent in the Mediterranean area due to defects in synthesis of β chains of hemoglobin. The aim of present study was to compare the effects of deferasirox and deferoxamine on iron overload and immunological changes in patients with blood transfusion-dependent β-thalassemia major and intermedia.
Patients and Methods:
This study involved 64 patients with known cases of β-thalassemia major or intermedia that has been treated with blood transfusion and iron chelators. Serum ferritin, serum iron, serum total iron binding, unsaturated iron-binding capacity (UIBC), and immunological parameters were assessed in deferoxamine and deferasirox-treated patients.
Results:
In deferoxamine-treated patients, serum ferritin levels were high (8160.33 ± 233.75 ng/dL) compared to deferasirox-treated patients (3000.62 ± 188.23 ng/dL;
P
< 0.0001), also there were significant differences in serum iron, total iron-binding capacity and UIBC (
P
< 0.0001) in deferasirox-treated patients compared to deferoxamine-treated patients. Immunological changes between two treated groups showed insignificant differences in levels of complements (C3 and C4) and immunoglobulin levels (IgM, IgG, and IgA)
P
> 0.05.
Conclusion:
This study indicated that deferasirox is more effective than deferoxamine regarding the iron overload but not in the immunological profile in patients with blood transfusion-dependent β-thalassemia.
[ABSTRACT]
[FULL TEXT]
[PDF]
[Mobile Full text]
[EPub]
[CITATIONS]
[PubMed]
7
4,855
164
Reporting adverse transfusion reactions: A retrospective study from tertiary care hospital from New Delhi, India
Sangeeta Pahuja, Vandana Puri, Gunjan Mahajan, Prajwala Gupta, Manjula Jain
January-June 2017, 11(1):6-12
DOI
:10.4103/0973-6247.200779
PMID
:28316433
Context:
Blood transfusion services have achieved newer heights in the last decade, with developments in cellular techniques, component separation, and integration of molecular methods. However, the system of recording and reporting of the adverse events related to blood transfusion is developing countries like India is grossly inadequate and voluntary in nature.
Aims:
This study was undertaken to analyze the retrospective data on adverse events related to blood transfusions in our hospital.
Subjects and Methods:
This retrospective study was done to examine all the transfusion related adverse events reported in a Regional Blood Bank Transfusion Centre of North India over a period of 9 years. Adverse transfusion events related to whole blood, red cell concentrates (RCCs), and all other components were analyzed and classified on the basis of their clinical features and laboratory tests. Average rate of transfusion reactions with the components was also assessed.
Statistical Analysis Used:
Categorical variables were analyzed using the Chi-square test.
P
> 0.05 was taken to indicate a significant difference.
Results:
During this period, a total of 1,60,973 blood/blood component units were issued by our blood bank to various departments of the hospital and 314 immediate transfusion events were reported. The rate of immediate transfusion reactions during the study was 0.19%. Average transfusion reaction rate with RCC was 0.25% with febrile nonhemolytic reactions being the most common type of adverse event (37.2%).
Conclusions:
Awareness should be increased among clinicians to correctly prevent, identify, and report transfusion-related adverse events. These measures should be implemented to increase blood transfusion quality and safety.
[ABSTRACT]
[FULL TEXT]
[PDF]
[Mobile Full text]
[EPub]
[CITATIONS]
[PubMed]
2
7,909
180
CASE REPORTS
Therapeutic leukapheresis in a tertiary care hospital: A case series
Raj Nath Makroo, Brinda Kakkar, Mohit Chowdhry, Soma Agrawal, Shishir Seth, Uday K Thakur
January-June 2017, 11(1):65-68
DOI
:10.4103/0973-6247.200772
PMID
:28316445
Patients presenting with hyperleukocytosis secondary to acute leukemia, with total leukocyte count or blast count more than 100,000/μL are often considered for leukapheresis, especially if clinical signs of leukostasis are present. Leukostasis is often associated with high morbidity and mortality in patients with leukemic processes. The main goal of management of hyperleukocytosis and/or leukostasis is to reduce the blast count before initiation of chemotherapy. Leukapheresis is often used prophylactically to prevent leukostasis or to provide symptomatic relief. We, as transfusion medicine specialists, present our experience of doing therapeutic leukapheresis in patients presenting with hyperleukocytosis with or without presenting features of leukostasis.
[ABSTRACT]
[FULL TEXT]
[PDF]
[Mobile Full text]
[EPub]
[CITATIONS]
[PubMed]
1
3,384
113
LETTERS TO THE EDITOR
Should we reconsider platelet content criteria for single donor platelets in West Bengal, India?
Rizwan Javed, Sabita Basu
January-June 2017, 11(1):69-70
DOI
:10.4103/0973-6247.200771
PMID
:28316446
[FULL TEXT]
[PDF]
[Mobile Full text]
[EPub]
[CITATIONS]
[PubMed]
1
2,526
67
Knowledge and practice of biosafety precautions in a developing tertiary care institute of North India
Anju Dubey, Atul Sonker
January-June 2017, 11(1):70-71
DOI
:10.4103/0973-6247.200776
PMID
:28316447
[FULL TEXT]
[PDF]
[Mobile Full text]
[EPub]
[CITATIONS]
[PubMed]
1
2,856
105
Chemiluminescence brings renaissance in TTI screening: Primi experientia
Diptiranjan Rout, Rahul Chaurasia, Poonam Coshic, Kabita Chatterjee
January-June 2017, 11(1):72-73
DOI
:10.4103/0973-6247.200777
PMID
:28316448
[FULL TEXT]
[PDF]
[Mobile Full text]
[EPub]
[CITATIONS]
[PubMed]
1
3,384
87
Median channel shift less than the cutoff in flow cytometric crossmatch: Not to be ignored!
Pranav Dorwal, Shyam Bihari Bansal, Rajni Chauhan, Dharmendra Jain, Vimarsh Raina, Vijay Kher
January-June 2017, 11(1):73-75
DOI
:10.4103/0973-6247.200773
PMID
:28316449
[FULL TEXT]
[PDF]
[Mobile Full text]
[EPub]
[CITATIONS]
[PubMed]
1
3,531
119
ORIGINAL ARTICLES
Factors affecting the quality of cryoprecipitate
Rajeswari Subramaniyan, Neelam Marwaha, Ashish Jain, Jasmina Ahluwalia
January-June 2017, 11(1):33-39
DOI
:10.4103/0973-6247.200778
PMID
:28316438
Background:
Many variables affect the quality of cryoprecipitate (CRYO). We investigated the effect of freezing techniques and ABO blood groups on the quality of CRYO with respect to factor VIII: C and fibrinogen levels.
Materials and Methods:
Ninety-six whole blood units each collected from in-house (Group I) and blood donation camps outside the hospital premises (Group II) were processed for CRYO preparation. Within each group, half the number of plasma units was frozen using blast freezer and another half using the conventional freezer. The CRYOs from blood groups A, B, and O were equally distributed, i.e. 32 within each of the Groups I and II. The fibrinogen and factor VIII: C levels in CRYO were analyzed using single-stage clotting assay.
Results:
In Group I, the mean ± standard deviation percentage recovery of factor VIII levels in CRYO prepared using the conventional freezer and blast freezer were 58.5% ±16.2% and 66.7% ±16.4%, respectively, and in Group II, it was 55.3% ±17.6% and 70.4% ±13.4%, respectively. Recovery of factor VIII was higher in CRYO prepared using blast freezer than that of CRYO prepared using conventional freezer (
P
< 0.000). In Group II, CRYOs prepared using blast freezer had higher percent recovery of fibrinogen than that of Group I. In both the groups, the mean factor VIII levels in blood group A were higher than that of factor VIII levels in the blood group O CRYO.
Conclusion:
The factor VIII recovery in CRYO improves significantly with higher baseline factor VIII: C levels, blood group A donor, and rapid freezing using blast freezer. Rapid freezing also increases the fibrinogen yield.
[ABSTRACT]
[FULL TEXT]
[PDF]
[Mobile Full text]
[EPub]
[CITATIONS]
[PubMed]
1
8,449
133
First Indian study to establish safety of immediate-spin crossmatch for red blood cell transfusion in antibody screen-negative recipients
Aseem Kumar Tiwari, Geet Aggarwal, Ravi C Dara, Dinesh Arora, Gautam Kumar Gupta, Vimarsh Raina
January-June 2017, 11(1):40-44
DOI
:10.4103/0973-6247.200774
PMID
:28316439
Background and Objectives:
The US Food and Drug Administration and American Association of Blood Banks approved the type and screen approach in 1980s, long after antibody screen (AS) was introduced in 1950s. The present study omits conventional anti-human globulin (AHG) crossmatch and replaces it with immediate-spin (IS) crossmatch as part of pretransfusion testing in AS-negative patients to study the safety and effectiveness of IS crossmatch in recipients.
Materials and Methods:
This prospective longitudinal study was conducted on over 5000 red cell units transfused to AS-negative patients admitted to the hospital. Pretransfusion testing comprised blood grouping and AS followed by IS crossmatch, at the time of issue of red cell unit. The patients were transfused IS compatible red cell units. AHG crossmatch was performed posttransfusion for all red cell units. Any incompatible AHG crossmatch was followed up as suspected transfusion reaction.
Results:
A total of 5023 red cell units were transfused to 2402 patients with negative AS. 99.7% IS compatible red cell units were also compatible on posttransfusion AHG crossmatch. Anti-P1 alloantibody was identified in one patient who was transfused two IS crossmatch compatible units but later both units were incompatible on AHG crossmatch. There was no clinical or serological sign of hemolysis in the patient.
Conclusion:
In AS-negative patients, IS crossmatch is as safe as conventional AHG crossmatch and can, therefore, replace conventional AHG crossmatch protocol.
[ABSTRACT]
[FULL TEXT]
[PDF]
[Mobile Full text]
[EPub]
[CITATIONS]
[PubMed]
1
4,106
90
CASE REPORTS
Snake in the grass: A case report of transfusion reactions due to contaminated donor arm disinfectant
Anju Dubey, Atul Sonker, Rajendra Chaudhary
January-June 2017, 11(1):50-52
DOI
:10.4103/0973-6247.200775
PMID
:28316441
Bacterial contamination of blood components remains an on-going challenge. In the majority of cases, organisms contaminating the blood components are a part of normal skin flora. Here, we report a case of bacterial contamination of blood units through contaminated donor arm disinfectant. There was a series of reactions due to random donor platelet (RDP) transfusion. The patients had features of septic transfusion reactions. On root cause analysis, spirit swabs used for disinfection of donors' arm were identified as the culprit and presence of
Clostridium difficile
was established. All the blood components prepared on the dates of implicated RDP units were removed from the stock and we replaced the existing 70% alcohol disinfectant with chlorhexidine-alcohol-based antiseptic rub. Further, no such transfusion reactions were reported. Implementation of good donor arm disinfection technique in addition to the use of blood bags with diversion pouch is proposed to be best preventive strategy for resource-poor settings.
[ABSTRACT]
[FULL TEXT]
[PDF]
[Mobile Full text]
[EPub]
[PubMed]
-
3,757
82
Alloimmunization in autoimmune hemolytic anemia patient: The differential adsorption approach
Ravi C Dara, Aseem Kumar Tiwari, Dinesh Arora, Subhasis Mitra, Devi Prasad Acharya, Geet Aggarwal, Jyoti Sharma
January-June 2017, 11(1):53-57
DOI
:10.4103/0973-6247.200782
PMID
:28316442
Patients of β-thalassemia major are dependent on regular blood transfusions for their entire lifetime. Development of antibodies against red blood cell (RBC) antigen which may be alloantibody or autoantibody, several times as a result of frequent red cell component transfusions, further complicates the subsequent transfusion therapy. Among the autoantibodies, warm-reactive autoantibodies are commoner and interfere in the pretransfusion testing. These RBC autoantibodies present in patient's serum potentially react with all the cells of antibody identification panel giving “pan-reactive” picture and making alloantibody identification complex. In this report, we present our approach in a thalassemia patient who presented with warm-type autoimmune hemolytic anemia, low hemoglobin of 5.8 g/dl, and three significant alloantibodies (anti-D, anti-S, and anti-Jk
b
) which were masked by pan-reactive warm autoantibody(s). Differential adsorption was used to unmask underlying alloantibodies. We suggest that differential adsorption procedure is an effective and efficient method for autoantibody adsorption, detection, and identification of masked alloantibody(s), especially in patients with low hemoglobin and history of recent blood transfusion.
[ABSTRACT]
[FULL TEXT]
[PDF]
[Mobile Full text]
[EPub]
[PubMed]
-
5,907
149
Low-density lipoprotein apheresis in a pediatric patient of familial hypercholesterolemia: Primi experientia from a tertiary care center in North India
Kanchan Dogra, Alpesh Goyal, Rajesh Khadgawat, Yashdeep Gupta, Diptiranjan Rout, Parag Prabhakar Fulzele, Rahul Chaurasia, Poonam Coshic, Kabita Chatterjee
January-June 2017, 11(1):58-61
DOI
:10.4103/0973-6247.200766
PMID
:28316443
Familial hypercholesterolemia (FH) is an autosomal dominant disorder due to mutation of apolipoprotein-B receptor gene causing severe dyslipidemia. Lifestyle modification and medical treatment attenuate the disease progression, but as these fail to control the blood cholesterol levels, low-density lipoprotein (LDL) apheresis comes forth as a treatment option. To the best of our knowledge, the following is the very first case of pediatric FH being treated by LDL-apheresis to be reported from India. A severely malnourished female child presented with yellowish skin lesions over different parts of the body, viz., bilateral Achilles tendon, both knees, elbows, both pinnae, and outer canthus of both eyes. She had a strong family history of borderline hypercholesterolemia and was diagnosed as a case of FH. She was maintained on diet modification. LDL-apheresis was planned as the cholesterol levels were not controlled with the diet modificationt. However, unavailability of an appropriate kit in India for LDL-apheresis led to the use of the modified PL1 kit meant for therapeutic plasma exchange procedures. We conducted two sessions of LDL-apheresis. After the first session, the LDL-cholesterol (LDL-C) level fell by 75.9% and the total cholesterol fell by 73.5%. A second procedure led to a decline in total cholesterol level by 18.6% and LDL-C by 19.46%. Subsequently, she was advised diet modification and statin therapy with regular follow-up after every 6 months. Thus, the cascade filtration technique is a safe and effective treatment option for removing the undesired lipoproteins.
[ABSTRACT]
[FULL TEXT]
[PDF]
[Mobile Full text]
[EPub]
[PubMed]
-
3,811
92
Anti-G with concomitant anti-C and anti-D: A case report in a pregnant woman
Rabeya Yousuf, Ahmad Nasirudin Mustafa, Siew-Ling Ho, Yee-Loong Tang, Chooi-Fun Leong
January-June 2017, 11(1):62-64
DOI
:10.4103/0973-6247.200770
PMID
:28316444
The G antigen of Rh blood group system is present in almost all D-positive or C-positive red cells but absent from red cells lacking D and C antigens. The differentiation of anti-D and anti-C from anti-G is not necessary for routine transfusion; however, during pregnancy, it is important because anti-G can masquerade as anti-D and anti-C with initial antibody testing. The false presence of anti-D will exclude the patient from receiving anti-D immunoglobulin (RhIG) when the patient actually is a candidate for RhIG prophylaxis. Moreover, patients with positive anti-D or anti-G are at risk of developing hemolytic disease of the fetus and newborn and need close monitoring. Thus, proper identification allows the clinicians to manage patients properly. This case report highlights a rare case of anti-G together with anti-D and anti-C in a pregnant woman. This report disseminates knowledge on identification of anti-G and its importance in pregnant women.
[ABSTRACT]
[FULL TEXT]
[PDF]
[Mobile Full text]
[EPub]
[PubMed]
-
6,786
136
LETTERS TO THE EDITOR
A case of anemia: How important is peripheral blood film before transfusing?
Pankaj Kumar, Geetanjali Jindal, Vishal Guglani
January-June 2017, 11(1):75-76
DOI
:10.4103/0973-6247.200780
PMID
:28316450
[FULL TEXT]
[PDF]
[Mobile Full text]
[EPub]
[PubMed]
-
2,663
77
ORIGINAL ARTICLES
ABO incompatible renal transplant: Transfusion medicine perspective
Raj Nath Makroo, Sweta Nayak, Mohit Chowdhry, Sanjiv Jasuja, Gaurav Sagar, NL Rosamma, Uday Kumar Thakur
January-June 2017, 11(1):45-49
DOI
:10.4103/0973-6247.200767
PMID
:28316440
Introduction:
Our study presents an analysis of the trends of ABO antibody titers and the TPE (Therapeutic Plasma Exchange) procedures required pre and post ABO incompatible renal transplant.
Materials and Methods:
Twenty nine patients underwent ABO incompatible renal transplant during the study period.The ABO antibody titers were done using the tube technique and titer reported was the dilution at which 1+ reaction was observed. The baseline titers of anti-A and anti-B antibodies were determined. The titer targeted was ≤8. Patients were subjected to 1 plasma volume exchange with 5% albumin and 2 units of AB group FFP (Fresh Frozen Plasma) in each sitting. TPE procedures post-transplant were decided on the basis of rising antibody titer with/ without graft dysfunction.
Results:
The average number of TPE procedures required was 4-5 procedures/patient in the pretransplant and 2-3/patient in the post-transplant period. An average titer reduction of 1 serial dilution/procedure was noted for Anti-A and 1.1/procedure for Anti-B. Number of procedures required to reach the target titer was not significantly different for Anti-A and Anti-B (
P
= 0.98). Outcome of the transplant did not differ significantly by reducing titers to a level less than 8 (
P
= 0.32). The difference in the Anti-A and Anti-B titers at 14th day post-transplant was found to be clinically significant (
P
= 0.042).
Conclusion:
With an average of 4-5 TPE procedures pretransplant and 2-3 TPE procedures post transplants, ABO incompatible renal transplantations can be successfully accomplished.
[ABSTRACT]
[FULL TEXT]
[PDF]
[Mobile Full text]
[EPub]
[PubMed]
-
4,492
122
Delta check for blood groups: A step ahead in blood safety
Raj Nath Makroo, Aakanksha Bhatia
January-June 2017, 11(1):18-21
DOI
:10.4103/0973-6247.200783
PMID
:28316435
Background:
Blood grouping is the single most important test performed by each and every transfusion service. A blood group error has a potential for causing severe life-threatening complications. A number of process strategies have been adopted at various institutions to prevent the occurrence of errors at the time of phlebotomy, pretransfusion testing, and blood administration. A delta check is one such quality control tool that involves the comparison of laboratory test results with results obtained on previous samples from the same patient.
Materials and Methods:
We retrieved the records of all transfusion-related incidents reported in our institute, between January 2008 and December 2014. Errors identified as “Failed Delta checks” and their root cause analyses (RCA) were reviewed.
Results:
A total of 17,034 errors related to blood transfusion were reported. Of these, 38 were blood grouping errors. Seventeen blood group errors were identified due to failed delta checks, where the results of two individually drawn grouping samples yielded different blood group results. The RCA revealed that all of these errors occurred in the preanalytical phase of testing. Mislabeling resulting in wrong blood in tube was the most commonly identified cause, accounting for 11 of these errors, while problems with correct patient identification accounted for 5 failed delta checks.
Conclusion:
Delta checks proved to be an effective tool for detecting blood group errors and prevention of accidental mismatched blood transfusions. Preanalytical errors in patient identification or sample labeling were the most frequent.
[ABSTRACT]
[FULL TEXT]
[PDF]
[Mobile Full text]
[EPub]
[PubMed]
-
4,438
95
A comparative study showing the potency of anti-C3d and anti-immunoglobulin G in polyspecific anti-human globulin using fresh and cryopreserved red blood cells
Kanchan Ahuja, Ranjan Kumar Satapathy, Garima Gulati, Surinder Singh
January-June 2017, 11(1):28-32
DOI
:10.4103/0973-6247.200769
PMID
:28316437
Background:
The antiglobulin test is used to determine red blood cells (RBCs) having surface-bound immunoglobulin G (IgG) and/or complement (C3b, C3d, C4b, and C4d) free in serum or attached to antigens on RBCs. In such circumstances, the quality of the anti-human globulin (AHG) which is used in routine cross-match/indirect agglutination test plays a vital role in blood transfusion medicine. For potency testing of polyspecific AHG, it is recommended by the Food and Drug Administration and the Centre for Biologics Evaluation and Research to use fresh O +ve RBCs within 1 hr of collection for sensitization with anti-C3d.
Aim and Objective:
Freshly collected red cells were cryopreserved and stored at a temperature of −70°C for 30 days. These cells were then sensitized with C3d and IgG after deglycerolization. Their viability was checked by potency testing using polyspecific AHG-containing anti-C3d and anti-IgG.
Materials and Methods:
Anonymous left over fresh whole blood samples were collected from the Indian Red Cross Society, New Delhi, with CPDA as an anticoagulant, and the samples were treated within 1 h of collection. ABO and Rh (D) phenotyping was performed by test tube method. RBCs and plasma from the same donor were used throughout the study.
Results:
In this comparative study, fresh RBCs (O +ve) maintained their viability after cryopreservation and were also found to be suitable for sensitization with C3d and IgG. The potency of polyclonal AHG did not differ significantly with fresh RBCs and cryopreserved RBCs for 30 days.
Conclusion:
This result suggests that the sensitization of fresh RBCs with IgG and C3d is not affected by using cryopreserved cells for 30 days.
[ABSTRACT]
[FULL TEXT]
[PDF]
[Mobile Full text]
[EPub]
[PubMed]
-
3,550
119
The Journal
Online Submission
Subscribe
Advertise
Addresses
Most Popular Articles
My Preferences
Contact us
|
Sitemap
|
Advertise
|
What's New
|
Copyright and Disclaimer
|
Privacy Notice
© 2006 - Asian Journal of Transfusion Science | Published by Wolters Kluwer -
Medknow
Online since 10
th
November, 2006